Description
FEATURES:
- Inlet & exhaust: 8″ dia flex duct adapter
- Blast gate on discharge for flow control
- Removable latches
- Sample port in lid
- Power: 120 vac, 1 ph, 10.6A
- Dimensions: 47″ L x 19″ W x 23″ H
- Unit weight: 140 lbs
The model MAC-21D (P/N FM41) is an adaptation of our model MAC-21 (P/N FM37) 500 CFM HEPA unit. This unit gives up some of the “modular features” in favor of a design assembled from explosion-proof components. The MAC-21D features an explosion proof motor and starter with a spark proof blower design (Class I Zone 2, AEx d nA IIA T3C [US] / Ex d nA IIA T3C [Canada]). Unlike the standard MAC-21, the blower/motor is not removable from the unit cart, and the flex hose inlet is not reconfigurable.
This unit has been evaluated to the applicable CSA standards for use in the United States under product Class 3812-81 (Fans and Blowers) and Canada under product Class 3812-01 (Fans and Blowers).
Unit does not include a HEPA filter. Purchase HEPA filter P/N AK78 separately. Information provided is subject to change. Please contact RPS directly for recent modifications.
Note that this unit has been specifically approved for use at Savannah River Site.
ITEM: SPARK ARRESTING PRE-FILTER
PART NUMBER: AK67
CUSTOM SIZES AND CONFIGURATIONS AVAILABLE UPON REQUEST.
ITEM: PRE-FILTER
PART NUMBER: AK66
CUSTOM SIZES AND CONFIGURATIONS AVAILABLE UPON REQUEST.
PART NUMBER: C104040
Sound attenuators effectively reduce blower discharge noise by up to 20% (DBA) with minimal loss of flow. Each unit is equipped with 8″ inlet and outlet collars for flexible duct (P/N CG53) and two wheels for handling.